What exactly is the difference between a surge protector and a fuse? Can a fuse protect the electronic devices from lightning instead of surge protector?
10.06.2025 05:42

but this device (an Inductor) … impedes the rapid changes in the current.
I post the exact comment here.
If the nominal power is 4,000 watts then the current at 230volts is 16 amps.
what exactly is a ‘surge’ protector?
Barnstars:
This is where this question deviates from being a 'generic' question, and becomes more specific.
How to use Google's AI-powered NotebookLM — 5 tips to get started - Tom's Guide
But it can get overloaded, and no longer works.
These devices are installed between the “hot” and “neutral” and protective ground.
It seems Mohan does not understand the difference between a comment and an Answer.
[old diagram got deleted by accident]
An AC voltage/ current source, and an ac inductive load.
Now when you have a certain ac resistance, then a current flows in a loop.
Deportees are being held in a converted shipping container in Djibouti, ICE says - NPR
There are three different concepts here that are getting confused.
He then describes the function of a fuse.
Edit 2024–10.
2024–10–11 [Victor Olarewsju Victor Olarewaju ]
Can the fuse protect the electronic devices from lightning instead of a surge protector.
so, what happens?
But during the surge, the fuse will not blow if it is a longer duration and lower value )10 to 50%).
What does a fuse do?
Because the load is inductive, the current lags the voltage.(by a bit).
Toyota Industries' shares nosedive on $33 billion buyout deal — steepest fall in 10 months - CNBC
This is a high voltage low current spike that comes down the line because of the power poles being struck, and the voltage suppressors activating on the primary side of the transformer.
A circuit breaker is similar, but is resettable.
The MOV will conduct when the voltage exceeds 50% of line voltage.
Lightning arrestor is a spark-gap device, and can be installed anywhere. What is important, is that the wire is thick enough to withstand the lightning bolt and conduct the energy away from the building.
This is where the MOV conducts again, and dissipated the energy.
So, the voltage could go up to 500 volts, and the fuse will not open up.
Here’s where to get free doughnuts on National Donut Day 2025 - Fortune
This is the picture of an electronic coil of wire wound around a core of magnetic material.
Mohan forgets that a fuse is a one-time device, and needs to be replaced if it is tripped.
2024–10–14 [Omar Gharbi Omar Gharbi ]
2024–09–27 [ Mohan Rajaratnam Mohan Rajaratnam ] . Thinks you can get free electricity from nothing : Mohan Rajaratnam's answer to Is it possible to generate free electricity at home using a magnet or other low-cost methods? If so, how does it work?
He then describes Rainy Season and Lightning.
but I think this circuit , shows a few more pieces.
2024–10–11 [Bobby Sanchez Bobby Sanchez ].
Is the question then , "why buy a surge supressor, if the fuse alone protects the electronic circuits from a lightning bolt?".
nine
(There is no concept of polarity, in the loop because the current changes direction 100 to 120 times a second (power frequency).
At the secondary, it is 1000 times less.)turns ratio). If it gets hit with a 100,000 volt bolt of lightning then the voltage arrestors conduct and clamp the voltage down to line voltage, ( but a small amount leaks down the line). This is the problem.
These are simplified answers to the original question, and does not change anything I wrote above.
Here is a simplified AC power diagram.
So, it’s possible that these devices from Trip Lite have addition suppression devices, these ones seem to be sturdy.
The third is lightning and “how it gets conducted into a home.”
This one hit behind the barn.
[image of Common-mode choke]
OK, this is Mohan Rajaratnam’s definition of a Surge suppressor.
So combined with a device called a MOV or Metal-oxide-resistor, then forms the 3rd part of a “surge suppressor “.
What is lightning?
Would individual surge supressors have save this equipment? most likely, since the surge supressor would take the jolt instead of the electronic components.
eight
First Sentence:
Fuses, on their own, then operate much slower than the MOV variable resistance, during the lightning strike.
(Dc diagram shown, AC is similar).
The bolt then partially travels down the line to your home.
Once the voltage goes over 0.0650 volts, then this fact can be used to amplify the difference, and turn the circuit breaker off , furthur down the line. Essentially that is what a RCD/GFCI does, it compares the incoming current, to the outgoing current, and if the difference between the two currents is over 5mA, then it trips the circuit breaker.
This is 'the assistant's answer'
a photo is worth a thousand words.
At one ohm, the resistor has a maximum of 1 watt power.
Upvotes:
There are two important concepts here.
One is “what exactly is in a ‘surge protector’ ? ”
One
He then asserts :
For this case there are devices called Metal oxide varistors (MOV).
At least they know the answer if they wanted it.
There is no harm in having the surge suppressor along with the fuse in the circuit. The fuse will not open up until the current melts the link. This will take time, and in the interim, that jolt will get transmitted into the power supplies.
And this is the problem alone. Is the power supply in the equipmemt designed with a lightning strike in mind? Some yes, others, no.
2024–10–10[John johnson John Johnson ]
This is a photo where a lightning bolt took out a home's complete mains distribution box, and a lot of electronic gear as well.
It’s been three xxx five werks, and there has been no response to my follow on query on his Commment to my answer.
This device then solves the entire problem.
But… the neutral is now “floating” because of the 1 ohm resistance.
“ A fuse is a device which protects the (circuit) against overload and short circuit.”
It also is a device that limits the change in current flow.
A fuse is a non-resetable over current circuit protector.
2024–10–00 [ Ammar Mahdi ] Ammar Mahdi
2024–10–16 [ OO OLAOYE OYEBODE ]
P = e* I, so since I is 16 amps, then the voltage dropped is 1/16 volt or 0.0650 volts.
When the current is 200% of the rated value , it will “go open” (the link metal melts) and protect the device.
so, the loop of wire then, when put together with another loop reduces the ‘noise’ on a power line.
In schematic diagrams this is the symbol for a fuse:
the problem then depends on "how fast does the fuse operate?".
This is an electronic circuit designed to clamp voltages so that the Voltage Potential that appears at the outlet is never going to exceed the nominal value.
“ A surge suppressor is the one which is connected at the input supply so that when there is a sudden change voltage it bypasses thereby protecting the (circuit) and electronic components”
The other is “what does a “fuse” do?”
“ … to protect building, lightning arrestor, is provided above building and directly connected to earth.”